Optimized breath detection algorithm in electrical impedance tomography
Linnéuniversitetet, Fakulteten för teknik (FTK), Institutionen för fysik och elektroteknik (IFE).ORCID-id: 0000-0003-2960-3094
Linnéuniversitetet, Fakulteten för teknik (FTK), Institutionen för fysik och elektroteknik (IFE).ORCID-id: 0000-0002-7018-6248
Swisstom AG, Switzerland.
Swisstom AG, Switzerland.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 39, nr 9, artikkel-id 094001Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Objective: This paper defines a method for optimizing the breath delineation algorithms used in Electrical Impedance Tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern. Approach: Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project. Main results: Three different algorithms are proposed that are improving the breath detector performance by adding conditions on 1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, 2) minimum tidal impedance amplitude and 3) minimum tidal breath rate obtained from Time-Frequency (TF) analysis. As a baseline the zero crossing algorithm has been used with some default parameters based on the Swisstom EIT device. Significance: Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the Receiver Operating Characterics (ROC). This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors.

sted, utgiver, år, opplag, sider
Institute of Physics Publishing (IOPP), 2018. Vol. 39, nr 9, artikkel-id 094001
HSV kategori
Forskningsprogram
Fysik, Elektroteknik alt Electrical engineering
Identifikatorer
URN: urn:nbn:se:lnu:diva-77552DOI: 10.1088/1361-6579/aad7e6ISI: 000444050400001PubMedID: 30074906Scopus ID: 2-s2.0-85054669051OAI: oai:DiVA.org:lnu-77552DiVA, id: diva2:1244995
Tilgjengelig fra: 2018-09-04 Laget: 2018-09-04 Sist oppdatert: 2019-08-29bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Khodadad, DavoodNordebo, Sven

Søk i DiVA

Av forfatter/redaktør
Khodadad, DavoodNordebo, Sven
Av organisasjonen
I samme tidsskrift
Physiological Measurement

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 90 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf