lnu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Jämförelse mellan subjektiva och objektiva metoder för bedömning av synnervsutträdet
Linnéuniversitetet, Fakulteten för Hälso- och livsvetenskap (FHL), Institutionen för medicin och optometri (MEO).
2018 (Svenska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)Alternativ titel
Comparison of subjective and objective methods to estimate the cup-to-disc ratio (Engelska)
Abstract [sv]

Syfte: Syftet med denna studie var att jämföra olika metoder för uppskattning av synnerven och gradering av cup/disk förhållandet.

Metod: 31 personer med friska ögon deltog i studien varav 25 kvinnor och 6 män. Undersökningen började med visuskontroll med hjälp av en log-MAR tavla. Därefter togs det bilder på synnerven på båda ögonen (med odilaterad pupill) med OCT som möjliggör en 3D visning av cupen och disken. Slutligen togs det bilder på synnerven via en funduskamera som visar en 2D bild. Fyra erfarna optiker fick bedöma 2D bilderna och gradera cup disk förhållandet subjektivt. Parametrarna som bedömdes var horisontell och vertikal cup/disk kvot, samt cup/disk area kvoten. Dessa parametrar jämfördes sedan med mätvärden som var uppskattade med hjälp av OCT maskinens program.

Resultat: Resultatet bestämdes med hjälp av ett parat t-test som visade en signifikant skillnad mellan den vertikala cup/disk kvoten (p<0,001) som var uppmätt och uppskattad av OCT och en funduskamera. Likadant för horisontell cup/disk kvoten och cup/disk area kvoten hittades det en signifikant skillnad (p <0,001) vid jämförelse av olika uppskattningsmetoderna. Optikernas cup/disk bedömning jämfördes och resultatet visade att bedömningarna inte var enade, då korrelationen var låg r <0,8.

Slutsats: Jämförelsen mellan de subjektiva och objektiva uppskattningarna av horisontell och vertikal cup/disk samt cup/disk area kvoten visade signifikant skillnad.

Abstract [en]

Aim: The aim of this study was to compare the different methods for estimating the optic nerve head and grading the cup-to-disc ratio.

Methods: In this study 31 subjects were included. The participants were aged between 19-32 years old and all of them had healthy eyes. An OCT was used to scan the optic nerve on both eyes and estimate the cup-to-disc ratio. The OCT scanning gives a 3D image of the optic nerve. Finally, the retina was photographed with a fundus camera, where the images were only 2D. Four experienced opticians graded the cup-to-disc ratio based on the 2D images. The parameters that got estimated were the horizontal and vertical cup-to-disc ratio, but even the cup-to-disc area ratio. Both subjective and objective parameters were compared to each other.

Results: A paired t-test was performed for the vertical cup-to-disc ratio that was both estimated by the graders and determined by the OCT; the t-test showed a statistically significant difference (p<0,001) between the two. Likewise, a paired t-test was performed for the horizontal cup-to-disc ratio and the cup-to-disc area ratio, which was graded by the opticians and determined by the OCT, and the results showed a significant difference (p<0,001).

The agreement between the graders were compared, and the correlation between the ratings of the cup-to-disc ratios was not high r<0,8.

Conclusion: The comparison between the subjective gradings from the opticians of the cup-to-disc ratio and the objective cup-to-disc parameters showed a significant difference.

Ort, förlag, år, upplaga, sidor
2018. , s. 24
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:lnu:diva-76068OAI: oai:DiVA.org:lnu-76068DiVA, id: diva2:1219773
Utbildningsprogram
Optikerprogrammet, 180 hp
Handledare
Examinatorer
Tillgänglig från: 2018-06-25 Skapad: 2018-06-17 Senast uppdaterad: 2018-06-25Bibliografiskt granskad

Open Access i DiVA

fulltext(1607 kB)179 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1607 kBChecksumma SHA-512
ef69eb40f3171c3a226f9433209ed566b7ce8f6e57155b66568c0cc2994c7f8933a91da0be413837d66979976fc55ebded7f95e7ef0a24833eb939ee29311f52
Typ fulltextMimetyp application/pdf

Av organisationen
Institutionen för medicin och optometri (MEO)
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 179 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 189 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf