lnu.sePublications
4748495051525350 of 154
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Momentstyv anslutning mellan vägg och gavelspets i trämoduler
Linnaeus University, Faculty of Technology, Department of Building Technology.
Linnaeus University, Faculty of Technology, Department of Building Technology.
2019 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Moment stiffness in connection between wall and gable tip in wooden modules (English)
Abstract [sv]

Studien omfattar anslutningen mellan vägg och gavelspets i ett prefabriceratenplanshus i trä. Huset är uppbyggt av saxtakstolar och få innerväggar för attdärigenom erhålla en öppen planlösning. Det medför att stabiliserandebyggnadsdelar saknas och horisontella vindlaster ger då upphov till oacceptabeltstora utböjningsdeformationer på anslutningen.

Syftet är att undersöka kapaciteten med avseende på moment, vindlast ochspännvidd i de befintliga lösningarna samt presentera en alternativ lösning somskulle kunna vara praktiskt tillämpbar. Utefter detta uppnås målet som är att lyftafram de parametrar som påverkar utböjningen.

Befintliga lösningar med förstärkning av balkar i materialet Kerto-S som ökarböjstyvheten undersöktes och analyserades. Två alternativa lösningar som klararutböjningskravet för en längre spännvidd dimensionerades.

Den första alternativa lösningen innefattar förutom två horisontella Kertobalkaräven en invändigt stående Kertopelarbalk som delvis kompenserar för avsaknadenav stabiliserande innerväggar. I den andra alternativa lösningen placeras fyra mindreKertopelarbalkar i väggkonstruktionen vilket gör att den horisontella vindlastenomfördelas. Gemensamt för de båda lösningarna är att anslutningsbalken fördelarvindlasten till en eller flera pelarbalkar som verkar avstyvande för konstruktionen.

Abstract [en]

This study embrace the connection between wall and gable tip in a prefabricatedsingle storey house in a wooden construction. The house is built by scissor trussesand few interior walls to achieve open floor plans. This causes that stabilizingbuilding components are missing and the effect of horizontal wind loads is causingunacceptable large deflection deformation in the connection. An existing solutionusing a Kerto beam which increase the bending stiffness was investigated andanalyzed.

The purpose of this work is to examine the capacity in the existing solutions and topresent an alternative solution that could be practical applicable. With thatknowledge accomplish the goal that is to emphasize the parameters that affects thedeflection.

Two alternative solutions that meets the deflection requirements for a longer spanwere designed. The first alternative solution contains, except for two Kerto beams,also an interior standing beam which partly make up for the lack of stabilizinginterior walls. In the second alternative solution, four smaller columns are locatedinside the wall construction to redistribute the load. Common for the both solutionsis that the connection beam obtains a smaller span by adding columns which insome extent constitute a stabilizing component.

Place, publisher, year, edition, pages
2019. , p. 108
Keywords [en]
Connection, moment stiffness, gable tip, gable wall, prefabricating, wind load.
Keywords [sv]
Anslutning, momentstyv, gavelspets, gavelvägg, prefabricering, vindlast
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:lnu:diva-88966OAI: oai:DiVA.org:lnu-88966DiVA, id: diva2:1348247
External cooperation
Myresjöhus AB
Subject / course
Byggteknik
Educational program
Civil Engineering Programme, Building and Construction, 180 credits
Supervisors
Examiners
Available from: 2019-09-10 Created: 2019-09-03 Last updated: 2019-09-10Bibliographically approved

Open Access in DiVA

fulltext(37341 kB)12 downloads
File information
File name FULLTEXT01.pdfFile size 37341 kBChecksum SHA-512
68d7512f649aa3a2730aa9386920b93af2757b6e8d714476d938e080b6fe105a96a6e449956bd5c4aaa5bd6186f77445cea415759a1509b3f59bfd5068450102
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Cicek, DavidEklund, Jennifer
By organisation
Department of Building Technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 12 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 59 hits
4748495051525350 of 154
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf