This paper relates to the mechanical performance of timber-glass composite beams, which take exceptional advantage of the combination of the materials involved. Beam bending tests were performed with beams made from float glass and heat-strengthened glass. Three different adhesive types were used: silicone, acrylate and epoxy. The test results show that, with a proper design, the timber is able to transfer load after glass failure and hence collapse is delayed and a ductile behavior can be obtained. The results from the tests were compared with an analytical method using the gamma-method and the agreement between the analytical method and the tests are shown to be excellent.