lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Horizontal Stabilisation of Sheathed Timber Frame Structures Using Plastic Design Methods - Introducing a Handbook Part 2: Design of Joints and Anchoring Devices
Luleå University of Technology.
Linnaeus University, Faculty of Technology, Department of Building Technology.
2016 (English)In: WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, Elsevier, 2016, p. 628-635Conference paper, Published paper (Refereed)
Abstract [en]

In this part 2, the practical design and strength of a number of different joints is described: (1) Sheathing-to-framing joints the plastic design method is based on the premise that the load-displacement relationship of the sheathing-to-framing joints has sufficiently large plastic deformation capacity; the sheathing-to-framing joints have great influence on the load-carrying capacity of the wall; (2) Stud-to-rail joints by utilizing the shear capacity of the stud-to-rail joints, the plastic design method can be simplified and the load-carrying capacity can be increased; (3) Hold down devices for the (leading) stud - the capacity of the tying down force of the hold down determines whether the shear wall will act as fully or partially anchored; tying down the shear walls by connecting them to the transverse walls leads to a 3-dimensioonal behaviour that is a very favourable for the load-carrying capacity and the stiffness of the shear wall; through transverse walls the anchoring of the leading stud can be reduced or eliminated (those types of transverse wall connections are not discussed in detail in this paper); and (4) Anchoring devices for the bottom rail in - partially anchored shear walls it is necessary that the bottom rail is anchored to the substrate against uplift. Characteristic values for the different types of joints are given. Also, joints between the panels in the walls, roofs and floors are described briefly. (C) 2016 The Authors. Published by Elsevier Ltd.

Place, publisher, year, edition, pages
Elsevier, 2016. p. 628-635
Series
Procedia Engineering, ISSN 1877-7058 ; 161
Keywords [en]
stabilisation, timber shear walls, plastic design methods, partially anchored, joints and anchorage devices, handbook
National Category
Civil Engineering
Research subject
Technology (byts ev till Engineering), Civil engineering
Identifiers
URN: urn:nbn:se:lnu:diva-59020DOI: 10.1016/j.proeng.2016.08.716ISI: 000387566500100Scopus ID: 2-s2.0-84997821101OAI: oai:DiVA.org:lnu-59020DiVA, id: diva2:1056779
Conference
World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium (WMCAUS), JUN 13-17, 2016, Prague, CZECH REPUBLIC
Available from: 2016-12-15 Created: 2016-12-14 Last updated: 2016-12-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Källsner, Bo

Search in DiVA

By author/editor
Källsner, Bo
By organisation
Department of Building Technology
Civil Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 101 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf