lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Innemiljö ombord en isbrytare: Upplevd luftkvalitet och personlig exponering för luftföroreningar
Linnaeus University, Faculty of Technology, Kalmar Maritime Academy.
2017 (Swedish)Independent thesis Basic level (university diploma), 5 credits / 7,5 HE creditsStudent thesisAlternative title
Indoor environment onboard an icebreaker : Perceived air quality and personal exposure to air pollutants (English)
Abstract [sv]

Att arbeta till sjöss innebär många olika arbetsuppgifter och utmaningar men få tänker på hur innemiljön påverkar besättningens hälsa. I och med de nya kraven i SECA området (svavelkontrollområde för Östersjön, Nordsjön och Engelska kanalen med utsläppskrav på max 0,10 viktprocent svavel i bränslet) där fartyg alltså krävs att köra på lågsvavligt bränsle, kan detta medföra en positiv förändring i fartygs innemiljö. Besättningens exponering för halter av luftföroreningar i innemiljön har studerats ombord isbrytaren Oden. Undersökningar genomfördes en gång under fartygets drift på tjockolja (HFO) och en gång med marin dieselolja (MDO) som bränsle. Halter av kvävedioxid (NO2), flyktiga organiska ämnen (VOC), inklusive bensen, och polycykliska aromatiska kolväten (PAH) mättes med personburna och stationära diffusiva provtagare. Besättningens upplevelse av luftkvalitet studerades med en enkätundersökning med avseende på den generella acceptansen av luftkvalitet, lukt, luftens karaktär såsom fräsch, torr, ren eller möglig, samt termisk komfort.

Den generella acceptansen av luftkvalitet var mycket hög; 0,8 på arbetsplatser och 0,9 i hytter, på en skala mellan -1 och 1. Medianhalterna av de kemiska luftföroreningarna från mätningar av den personliga exponeringen låg mycket under Arbetsmiljöverkets hygieniska gränsvärden och även under rekommenderade riktvärden för god luftkvalitet inomhus. Bränslebytet gav en minskning av den personliga exponeringen för kvävedioxid och bensen som är statistiskt signifikant. Resultaten visar även på att besättningen ombord på fartyget är nöjda med sin innemiljö och att en viss minskning av ämnen finns efter bränslekonverteringen.

Abstract [en]

The crew's working as a mariner means many different tasks and challenges but few think about the effects of the indoor environment on the human health. Now when the new SECA regulations are in force vessels has been forced to convert to new low- sulphur fuel and this can lead to a positive change in the vessels indoor environment. Exposure and levels of air pollutants in indoor environment have been studied onboard the icebreaker Oden. Investigations were performed once during the vessel’s operation on heavy fuel oil (HFO) and once with marine diesel (MD) as fuel. Concentration of nitrogen dioxide (NO2), volatile organic compounds (VOCs), including benzene, and polycyclic aromatic hydrocarbons (PAH) were measured with personal and stationary diffusive samplers. The crew's perception of air quality was studied by a questionnaire survey with regard to the general acceptability of air quality, odor, and air characteristics such as fresh, clean, dry or moldy, and thermal comfort.

The general acceptance of the air quality was very high; 0.8 and 0.9 in the workplaces and in cabins, respectively, on a scale from -1 to 1. The decrease in personal exposure to nitrogen dioxide and benzene was statistically significant. Difference between the concentrations of volatile organic compounds was not statistically significant. The indoor air quality has improved in several aspects after the fuel conversion. The results from the questionnaires show that the crew was overall satisfied with their indoor environment. The results of the measurements show a decrease of substances after the conversion.

Place, publisher, year, edition, pages
2017. , p. 37
Keywords [en]
Indoor environment, exposure, air, quality, fuel, conversion
Keywords [sv]
Innemiljö, miljö, exponering, luft, kvalitet, bränsle, konvertering
National Category
Other Engineering and Technologies not elsewhere specified
Identifiers
URN: urn:nbn:se:lnu:diva-60013OAI: oai:DiVA.org:lnu-60013DiVA, id: diva2:1067233
External cooperation
Svenska miljöinstitutet
Subject / course
Master Mariner
Educational program
Nautical Science Programme (3 years), 180 credits
Supervisors
Examiners
Available from: 2017-01-20 Created: 2017-01-20Bibliographically approved

Open Access in DiVA

fulltext(1163 kB)69 downloads
File information
File name FULLTEXT01.pdfFile size 1163 kBChecksum SHA-512
1aae82678f98494a14ae1253ab55ab6afe6a6c0d95959944427e18e9b5f3f2258b7b691d0972b64e0f54217149e0d77e2fed5f1f7929d64d3d1d4a1e1304369e
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Hjelmér, Björn
By organisation
Kalmar Maritime Academy
Other Engineering and Technologies not elsewhere specified

Search outside of DiVA

GoogleGoogle Scholar
Total: 69 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 274 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf