Fixationsdisparitet: En jämförelse av tre olika tester
Linnaeus University, Faculty of Health and Life Sciences, Department of Medicine and Optometry.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Syfte: Syftet med studien var att jämföra tre olika metoder (Mallettenheten, Saladinkortet och Wessonkortet) för att mäta fixationsdisparitet, se ifall metoderna hade en bra repeterbarhet samt jämföra resultaten från fixationsdisparitetstesterna med den uppmätta forin.Material och metod: I studien deltog 19 personer mellan 20–31 år, alla hade samsyn. Undersökningen utfördes i en ordning som gjorde att ögonen skulle tröttas ut så lite som möjligt för att inte påverka resultatet. Den började med anamnes, refraktion, forimätningar med modifierad Thorington på avstånd och på nära håll och sedan utfördes mätningar av fixationsdisparitet, varje metod utfördes tre gånger för att få fram ett medelvärde. Undersökningen avslutades med mätning av KNP, ackommodationsamplitud och vergensmätningar.Resultat: 11 av 19 försökspersoner hade någon fixationsdisparitet (FD) enligt Mallett, Saladin eller Wesson. Då Mallett endast mäter den associerade forin och inte FD så användes inte den i jämförelserna. Studien visar en statistiskt signifikant skillnad i uppmätt FD mellan Wesson och Saladin (p = 0,027). En Bland-Altman analys visade att skillnaden mellan mätresultaten blev högre ju högre fixationsdispariteten var. Repeterbarheten var god för Wesson (ICC = 0,95) och Mallett (ICC = 0,87), men något lägre för Saladin (ICC = 0,71). En envägs- RM ANOVA visade inga signifikanta skillnader mellan de tre mätningarna för någon av metoderna. 47 % av försökspersonerna hade en FD som gick åt samma håll som den uppmätta forin. 10 % hade FD som gick åt motsatt håll från forin. Varken Wesson eller Saladin visade någon signifikant korrelation med forin: Wesson (p = 0,11, R = 0,15) och Saladin (p = 0,08, R = 0,17).Slutsats: Studien visar att det fanns en signifikant skillnad mellan Saladintestet och Wessontestet och att de således inte är utbytbara med varandra. Repeterbarheten har varit god för två av tre metoder. Det här studien har visat att om fixationsdispariteten ska mätas kliniskt kan det vara bra för undersökaren att bestämma sig för ett test och bara använda det, det går inte att dra slutsatsen helt då detta bör testas på en större grupp försökspersoner.

Abstract [en]

The aim of this study was to compare three clinical tests used for measuring fixation disparity. The correlation between fixation disparity and phoria was evaluated and the repeatability for each method.This study included 19 subjects (aged from 20 to 31 years); all had functional binocular vision. The order of the tests in the examination was chosen to prevent fatigue from effecting the results. Following case history, binocular refraction, and phoria measurements at distance and near, the examination proceeded in measurement of fixation disparity with each of the three tests; three measurements were performed for each, and averaged. The examination concluded with measurements of NPC, amplitude of accommodation and vergences.Eleven of 19 subjects had FD to some degree according to Mallett, Saladin or Wesson. Since the Mallett unit only measures the associated phoria, the results could not be used in this study.This study shows a significant difference in measured FD between Wesson and Saladin (p=0.027). A Bland-Altman analysis showed a significant difference between the results; it showed that the higher the fixation disparity the greater the difference between the two measurements (p <0.0001). The repeatability was good for Wesson (ICC = 0.95) and Mallett (ICC = 0.87), however lower for Saladin (ICC = 0.71). A One Way- RM ANOVA showed no significant difference between the three measurements for each method. FD deviated in the same direction as the measured phoria for 47 % of the subjects; 10 % had FD that deviated in the opposite direction from the measured phoria. Wesson and Saladin showed no significant correlation to the phoria: Wesson (Pearsson r = 0.15; p = 0.11), and Saladin (Pearsson r = 0.17; p= 0.08).The study shows that there is a significant difference in the results of fixation disparity between the Saladin card and the Wesson card indicating that these methods can’t be used interchangeably. Repeatability was better for Mallett and Wesson but not so good for Saladin. There was a significant correlation between phoria and fixation disparity in means of the direction of deviation i.e. an exophoria is often followed by an exo fixation disparity.In a clinical setting, it might be advisable to adopt one single method and not compare results with those obtained by other instruments.

Place, publisher, year, edition, pages
2017. , p. 23
Keywords [sv]
Fixationsdisparitet, Mallett, Saladin, Wesson, Repeterbarhet, Dissocierad fori
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:lnu:diva-65452OAI: oai:DiVA.org:lnu-65452DiVA, id: diva2:1110907
Subject / course
Optometry
Educational program
Optometry Programme, 180 credits
Supervisors
Examiners
Available from: 2017-06-29 Created: 2017-06-16 Last updated: 2017-06-29Bibliographically approved

Open Access in DiVA

fulltext(1549 kB)186 downloads
File information
File name FULLTEXT01.pdfFile size 1549 kBChecksum SHA-512
fdea7a9d80dfe3b26db6b0bf42c7546124c6dbf88bed068b6b2e0e09cf0f35a001937c24aa46db910dbcdf8eac402762b0b57860bc5f21390349ece0f502a413
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Finnström, Caroline
By organisation
Department of Medicine and Optometry
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 186 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 331 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf