lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effekten av inducerad monokulär och binokulär dimning på stereoseende och visus
Linnaeus University, Faculty of Health and Life Sciences, Department of Medicine and Optometry.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Syfte: Syftet med den här studien var att se ackommodationens roll i inducerad hyperopi på stereoseende och visus både monokulärt och binokulärt på avstånd och nära.

Metod: Urvalet bestod av 14 emmetroper med åldern 20-28 år med en medelålder på 24 år. Stereoseende och visus mättes upp på 6 m och 40 cm både monokulärt och binokulärt. Visus mättes med logMAR tavla och stereoseendet med Randot på 6 m med test chart 2000, Dutch organisation for Applied Scientific Research (TNO) stereotest (Lameris Ootech, Ede, Netherlands)  för stereoseende och en när logMAR tavla för 40 cm. Med inducering av minuslinserna -1D, -2D och -3D på alla tester.

Resultat: Monokulär inducering på stereoseendet på avstånd gav signifikant skillnad  på alla styrkorna (p<0,05). Binokulär inducering på avstånd gav inte en signifikant skillnad på -1D (p>0,05) men signifikant skillnad på -2D och -3D (p<0,05). Monokulär inducering på nära gav en signifikant skillnad på alla styrkorna (p<0,05). Binokulär inducering på nära gav inte en signifikant skillnad på -1D och -2D (p>0,05) men en signifikant skillnad på -3D (p<0,05). Visus både avstånd och nära gav ingen signifikant skillnad på binokulärt eller monokulärt (p>0,05).

Slutsats: Även om stereoseendet påverkas av både monokulär och binokulär inducering av minuslinser påverkas inte visus i denna studie. Studien visar även att monokulär inducering påverkar stereoseendet mer än vad binokulär inducering gör.

Abstract [en]

This study investigated the effect of both monocular and binocular induced visual stress with minus lenses, to see the difference of effect on visual acuity and stereopsis.

 

The study had 14 emmetropes with mean age of 24. Stereopsis and visual acuity was measured on both 6 m and 40 cm, using logMAR visual chart for visual acuity and Randot test for stereopsis on 6 m with test chart 2000, TNO test for stereopsis and near logMAR chart for visual acuity at 40 cm. On all the test there was induced visual stress using minus lenses of power -1D, -2D and -3D on the dominant eye for monocular and for binocular.

 

The monocular blur on stereopsis for distance was a significant difference on all lenses (p<0.05). Binocular blur on distance did not give a significant difference regarding -1D (p>0.05) but gave a significant difference on both -2D and -3D (p<0.05). Monocular blur on near gave a significant difference on all lenses (p<0.05). Binocular blur on near did not give a significant difference on -1D and -2D (p>0,05) but on -3D there was a significant difference (p<0.05). Visual acuity gave on both distance and near no significant difference in any of the tests (p>0.05).

 

The study shows that even tough stereopsis was affected on both monocular and binocular induced visual stress there was no effect on visual acuity. It also shows that monocular induced stress affects stereopsis more than that of binocular induced stress.

Place, publisher, year, edition, pages
2017. , p. 22
Keywords [sv]
Stereoseende, visus, TNO
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:lnu:diva-65524OAI: oai:DiVA.org:lnu-65524DiVA, id: diva2:1111369
Subject / course
Optometry
Educational program
Optometry Programme, 180 credits
Supervisors
Examiners
Available from: 2017-06-29 Created: 2017-06-18 Last updated: 2017-06-29Bibliographically approved

Open Access in DiVA

fulltext(998 kB)88 downloads
File information
File name FULLTEXT01.pdfFile size 998 kBChecksum SHA-512
6768661d9727a9a047d0cbd9517cd5cfca45facad6d8f422e5ce4980dd77d1f6de870f88104f4e6fb36c2f9bafe492d2d9bbbd694bba18d9a26796a1aefb3846
Type fulltextMimetype application/pdf

By organisation
Department of Medicine and Optometry
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 88 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 67 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf