Kostnadsbesparing med avseende på energieffektiviserande åtgärder med avgränsning till fönsterbyte och tilläggsisolering
Linnaeus University, Faculty of Technology, Kalmar Maritime Academy.
Linnaeus University, Faculty of Technology, Kalmar Maritime Academy.
2018 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Cost savings with regard to energy efficiency measures with delimitation of window change and additional insulation (English)
Abstract [sv]

Linnéuniversitetet

Sjöfartshögskolan i Kalmar

Utbildningsprogram:                                                                          Drift- och underhållsteknik

Arbetets omfattning:                                                                         Självständigt arbete om 15 HP

Titel:                                                                     Kostnadsbesparing med avseende på energieffektiviserande åtgärder med avgränsning till fönsterbyte och tilläggsisolering.

Författare:                                                                                             Fredrik Svensson och Johan Bengtsson

Handledare:                                                                                          Henrik Wärnberg

 

Sammanfattning

2017 års medelpris för el hamnade på cirka 30 öre per kWh. Det är åtta procent högre än för 2016 och hela 32 procent högre än 2015, då elpriset var väldigt lågt. 2017 års elpris är det högsta sedan 2013. Fortsättningsvis spår Bixia låga elpriser de kommande åren vilket beror på utbyggnaden av förnybar energi och att kärnkraftverket Olkilouto 3 i Finland tas i drift. Bixia räknar med att den nordiska elmarknaden kommer att ha en förstärkt energibalans fram till 2019. Efter år 2019 kommer energibalansen att försvagas, beroende på stängningen av Ringhals 1 och 2 och ökad export av el ut från Norden, säger Martina Rosenberg på Bixia. En försvagad energibalans innebär en högre prisnivå. Projektet syftar till att kartlägga omfattningen av energiförluster, i ett privat hushåll, till följd av transmission och därefter göra en bedömning om energibesparingsåtgärder, i form av tilläggsisolering och fönsterbyte, skulle vara en ekonomisk lönsam investering. Genom minskad energianvändning ger dessa investeringar ett positivt tillskott i energibalansen och kan även bidra till en bättre inomhusmiljö.

 

Projektet följer en metod där kvalitativa experiment har utförts genom mätningar på klimatskärmen. Denna mätning har gjorts med hjälp av en termografikamera där bilder har detekterat otätheter i klimatskärmen, så kallade köldbryggor. Energiförluster, till följd av transmission, har sedan beräknats med handberäkningsmetoder och utförts för en rad olika storheter, exempelvis värmeledningsmotstånd och värmegenomgångskoefficienter. Utöver detta har den specifika klimatskärmen delats upp i flera sektioner respektive skikt för att strukturerade beräkningar skulle kunna utföras enligt den beräkningsgång detta projekt efterföljt.

 

Undersökningen visar att åtgärderna bidrar till omkring 4 gånger mindre energiförluster gällande energifönster och 2 gånger mindre för väggen jämfört med värdena före åtgärder. Återbetalningstiden är dock betydligt längre för energifönstren då detta är en betydligt mer kostsam investering. För PVC-fönster landar återbetalningstiden på ca 27 år och för aluminiumbeklädda träfönster är återbetalningstiden i detta fall över 40 år mot ca 20 år för tilläggsisoleringen.

Abstract [en]

Linnaeus University

Kalmar Maritime AcademyEducation programs:                                          Operation and MaintenanceScope of work:                                                    Independent work of 15 HPTitle:                                                                          Cost savings with regard to energy efficiency                                          measures with delimitation of window change and additional insulationAuthor:                                                                Fredrik Svensson and Johan Bengtsson Supervisor:                                                          Henrik Wärnberg Abstract The 2017 average electricity price ended at around 30 Swedish “öre” per kWh. It is eight percent higher than in 2016 and 32 percent higher than in 2015, when the price for the electricity was much lower. The 2017 electricity price is the highest since 2013. Continuingly, Bixia's low electricity prices predict the next few years, which is due to the expansion of renewable energy and that the Olkilouto 3 nuclear power plant are put into use in Finland.

 

Bixia expects the Nordic electricity market to have a strengthened energy balance until 2019. After 2019, energy balance will weaken due to the closure of Ringhals 1 and 2 and increased exports of electricity from the Nordic countries, says Martina Rosenberg from Bixia. A weakened energy balance means a higher price level.

 

The project intention is to mapping the extent of energy losses, in a private household, due to transmission and subsequently assessing energy saving measures, in the form of additional insulation and exchange of windows, would be a profitable investment. Through reduced energy consumption, these investments provide a positive boost to the energy balance and can also contribute to a better indoor environment.

 

The project follows a method where qualitative experiments have been carried out through measurements on the climate screen. This measurement has been done by using a thermographic camera where images have detected thermal unevennesses in the climate screen that is called cold bridges. Energy losses due to transmission have then been calculated by hand calculation methods and performed for a variety of quantities, such as heat conductivity resistors and thermal coefficients. In addition, the specific climate screen has been divided into several sections and layers, so that structured calculations could be performed according to the calculation process followed by this project.

 

The survey shows that the measures contribute to is about 4 times less energy losses on energy windows and 2 times less for the wall than the pre-measure values. However, the repayment time is significantly longer for the energy windows, as this is a significantly more costly investment. For PVC windows, the repayment period is approximately 27 years. For aluminum clad wood windows, the repayment period in this case is over 40 years to about 20 years for the additional insulation.

Place, publisher, year, edition, pages
2018. , p. 71
Keywords [en]
Energy savings, Energy-efficient measures, Transmission, Additional insulation, Window changes, Payback
Keywords [sv]
Energibesparing, Energieffektiva åtgärder, Transmission, Tilläggsisolering, Fönsterbyte, Återbetalningstid
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:lnu:diva-74430OAI: oai:DiVA.org:lnu-74430DiVA, id: diva2:1208835
Educational program
Operation and Maintenance Engineering, 180 credits
Supervisors
Examiners
Available from: 2018-05-21 Created: 2018-05-21 Last updated: 2018-05-21Bibliographically approved

Open Access in DiVA

fulltext(2085 kB)34 downloads
File information
File name FULLTEXT01.pdfFile size 2085 kBChecksum SHA-512
f83595f1729bcd531733aec6fcd9f4d57eb38842dcde65b7dc108c0b6ae150ed30b0075e6351e1faad9a4f3b60c1093e606d49a48f44e981955dd010741e5ef1
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Svensson, FredrikBengtsson, Johan
By organisation
Kalmar Maritime Academy
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 34 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 81 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf