Tillämpning av Eurokod vid tillståndsbedömning av äldre murverksbyggnader.: En fallstudie över murverkskonstruktionen i området Aspebacken i Ljungby kommun.
2020 (Swedish)Independent thesis Basic level (professional degree), 180 HE credits
Student thesisAlternative title
Application of Eurocode for structural assessment of older masonry buildings. : A case study of the masonry structure in the Aspebacken area in Ljungby Municipality (English)
Abstract [sv]
Studien fokuserar på äldre murverkskonstruktioner och ifall Eurokod går att tillämpas på dessa konstruktionerna. Det byggs inte särskilt ofta murverkskonstruktioner vid nybyggnation nu för tiden och anledningen till det är högst troligen materialet betong. Betong, som är snabbare och billigare att bygga med, har konkurrerat ut alla utom fyra av ungefär 500 tegelbruk i Sverige. Detta har medfört att kunskapen om hur murverken bör restaureras inte finns i så stor utsträckning.
Vid datainsamlingen i rapporten undersöktes tidigare forskning inom det valda området. En fallstudie, litteraturstudie samt teoretiska beräkningar genomfördes för att uppnå syftet med examensarbetet. Resultatet från fallstudien tyder på att en av väggarna i murverkskonstruktionen inte uppfyller Eurokodens samtliga krav och den är därför inte lämplig att ha i bruk. I byggnaden från fallstudien fanns även fuktrelaterade skador, sprickor och sättningar.
För att kunna restaurera den studerade byggnaden krävs stora åtgärder och därför anses byggnaden vara ett rivningsobjekt.
Abstract [en]
The study focuses on older masonry structures and if Eurocode can be applied to these structures. It is not very often that masonry structures are built for new construction nowadays and the reason for this is most likely concrete. Concrete, which is faster and cheaper to build with has competed out all but four of about 500 brickworks in Sweden. This means that knowledge of how masonry constructions could be restored is very limited.
In the collection of data for the thesis, previous research in the chosen area was examined. A case study, literature study and theoretical calculations were conducted in order to achieve the purpose of the thesis. The results indicate that the case study masonry construction walls do not meet all the Eurocode requirements and are not suitable for use. There were also moisture-related damages, cracks and settlements in the building.
In order to be able to restore the studied building much work will be required, and therefore the building is better to be considered a demolition object.
Place, publisher, year, edition, pages
2020. , p. 60
Keywords [en]
Masonry construction, brickwork, mortar
Keywords [sv]
Murverkskonstruktion, tegelbruk, murbruk
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:lnu:diva-96991OAI: oai:DiVA.org:lnu-96991DiVA, id: diva2:1451426
Subject / course
Byggteknik
Educational program
Civil Engineering Programme, Building and Construction, 180 credits
Presentation
(Swedish)
Supervisors
Examiners
2020-07-032020-07-022020-07-03Bibliographically approved