lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Prestressed hollow core slabs for topped slim floors: Theory and research of the shear capacity
Linnaeus University, Faculty of Technology, Department of Building Technology. Cracow University of Technology, Poland. (Concrete Structures)ORCID iD: 0000-0001-6133-3624
Pekabex Bet. S. A., Poland.ORCID iD: 0000-0002-1444-3326
2021 (English)In: Engineering structures, ISSN 0141-0296, E-ISSN 1873-7323, Vol. 241, article id 112464Article in journal (Refereed) Published
Sustainable development
SDG 9: Build resilient infrastructure, promote inclusive and sustainable industrialization, and foster innovation
Abstract [en]

This research paper discusses the influence of the flexibility of girders in Slim Floor structures on the reduced load capacity of prestressed HC slabs. The current state of knowledge in the field of the transverse behaviour of hollow core slabs is presented. Contradictory information provided in the literature as well as the computational comparative analysis of the existing theoretical models has demonstrated the need for better recognition of the issue of the effect of reinforced concrete topping layer on the load capacity of HC slabs. The paper includes the presentation of experimental tests, the purpose of which was to reproduce the actual work conditions of hollow core slabs depending on their location on the floor and the numerical analyses supplemented these studies. As a result of the conducted tests and analyses, it was found that the increased flexibility of the support beam resulted in an adverse change in the stress state of the hollow core slab, which may lead to the exceedance of the limit state of shear capacity, while laying an additional layer of structural topping on precast hollow core slabs significantly increased the shear capacity of the floor, and thus the safety of the structure. The research also indicates that in all the tested topped elements full composite action up to the failure was shown.

Place, publisher, year, edition, pages
Elsevier, 2021. Vol. 241, article id 112464
Keywords [en]
Concrete topping, Finite Element Modelling, Flexible support beam, Full-scale test, Precast hollow core slab, Slim floor, Shear capacity
National Category
Building Technologies
Research subject
Technology (byts ev till Engineering), Civil engineering
Identifiers
URN: urn:nbn:se:lnu:diva-103109DOI: 10.1016/j.engstruct.2021.112464ISI: 000657671800002Scopus ID: 2-s2.0-85105349485Local ID: 2021OAI: oai:DiVA.org:lnu-103109DiVA, id: diva2:1553184
Available from: 2021-05-07 Created: 2021-05-07 Last updated: 2021-07-08Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Derkowski, Wit

Search in DiVA

By author/editor
Derkowski, WitSurma, Mateusz
By organisation
Department of Building Technology
In the same journal
Engineering structures
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 129 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf