lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Novel Condition Monitoring Procedure for Early Detection of Copper Corrosion Problems in Oil-Filled Electrical Transformers
Linnaeus University, Faculty of Technology, Department of Mechanical Engineering.ORCID iD: 0000-0003-2634-3987
Linnaeus University, Faculty of Technology, Department of Mechanical Engineering.ORCID iD: 0000-0002-2637-6175
Ministry of Electricity and Water, Kuwait.
Ministry of Electricity and Water, Kuwait.
2021 (English)In: Energies, E-ISSN 1996-1073, Vol. 14, no 14, article id 4266Article in journal (Refereed) Published
Abstract [en]

The negative impacts of catastrophic fire and explosion accidents due to copper corrosion problems of oil-filled electrical transformers are still in the spotlight due to a lack of effective methods for early fault detection. To address this gap, a condition monitoring (CM) procedure that can detect such problems in the initial stage is proposed in this paper. The suggested CM procedure is based on identified measurable variables, which are the relevant by-products of the corrosion reaction, and utilizes an Early Fault Diagnosis (EFD) model to detect and solve the copper corrosion problems. The EFD model includes a fault trend chart that can track a fault progression during the useful life of transformers. The purpose of this paper is to verify and validate the effectiveness of the suggested CM procedure by an empirical study in a power plant. The result of applying this procedure was early detection of copper corrosion problems in two transformers with suspected copper corrosion propagation from a total of 84. The corrective action was adding an optimized amount of a passivator, an anticorrosion additive, to suppress the corrosion reaction at the correct time. The main conclusion of this study is the importance of early detection of transformer faults to avoid the negative impacts on societal, company, and individual levels.

Place, publisher, year, edition, pages
MDPI, 2021. Vol. 14, no 14, article id 4266
Keywords [en]
CBM strategy, condition monitoring, copper corrosion, fault detection, transformer failures
National Category
Electrical Engineering, Electronic Engineering, Information Engineering Reliability and Maintenance
Research subject
Technology (byts ev till Engineering), Mechanical Engineering
Identifiers
URN: urn:nbn:se:lnu:diva-106697DOI: 10.3390/en14144266ISI: 000676455700001Scopus ID: 2-s2.0-85111171222Local ID: 2021OAI: oai:DiVA.org:lnu-106697DiVA, id: diva2:1590419
Available from: 2021-09-02 Created: 2021-09-02 Last updated: 2023-08-28Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Jadim, RamseyKans, Mirka

Search in DiVA

By author/editor
Jadim, RamseyKans, Mirka
By organisation
Department of Mechanical Engineering
In the same journal
Energies
Electrical Engineering, Electronic Engineering, Information EngineeringReliability and Maintenance

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 132 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf