Miljöavtryck från datacenter i Sverige: En kombinerad studie om miljöpåverkan och möjligheten till strategisk lokalisering
Linnaeus University, Faculty of Health and Life Sciences, Department of Biology and Environmental Science.
2022 (Swedish)Independent thesis Advanced level (degree of Master (One Year)), 20 credits / 30 HE creditsStudent thesis
Sustainable development
SDG 13: Take urgent action to combat climate change and its impacts by regulating emissions and promoting developments in renewable energy
Abstract [sv]

En allt större efterfrågan på digitala tjänster har medfört att datacentersektorn växt i en allt snabbare takt de senaste decennierna, inte minst i Sverige. Flera internationella teknikjättar, såsom Amazon Web Services och Microsoft, attraheras av gynnsamma förhållanden i landet. Serverhallar är energiintensiva byggnader, vilka globalt orsakar betydande utsläpp av växthusgaser och konsumtion av vatten. Således ökar behovet av att övervaka miljöpåverkan och optimera sektorns miljömässiga förutsättningar. Examensarbetet tillgodoser detta genom att presentera en helhetsbild över sektorns miljöavtryck i Sverige, utifrån kvantifiering av koldioxid- och vattenavtrycket och identifiering av möjligheterna att reducera avtrycket. Metoden innefattar användandet av faktiska data (t.ex. från enkätundersökning), tillsammans med generella data och metoder från tidigare studier, för att möjliggöra en estimering av sektorns elanvändning. Emissions- och vattenkonsumtionsfaktorer beräknades för Sveriges elområden, med hänsyn till använda primärenergikällor vid elproduktion, tillsammans med respektive datacenters årliga elanvändning fastställdes sedan det indirekta miljöavtrycket. Möjligheten till att minimera miljöpåverkan med strategisk lokalisering undersöktes, genom klassificering av landets kommuner. Klassificeringen baserades på geografiska data, vilka påverkar ett datacenters förutsättningar att återvinna spillvärme, tillgång till förnybar energi, potentialen för frikyla och risken att orsaka vattenbrist. Resultatet indikerar att ungefär 0,3 % (1,3 * 105 tonCO2eq/år) av Sveriges koldioxidavtryck och 14 % (4,2 * 107 m3/år) av industrins sammanlagda vattenkonsumtion kan allokeras till datacenter. Miljöavtrycket kan kopplas till sektorns höga elanvändning, vilket estimerades till cirka 5,4 % av Sveriges slutgiltiga elanvändning år 2020. Möjligheten till etableringen av datacenter med låg miljöpåverkan bedömdes överlag som bättre i norra delen av landet, genom relativt gynnsamma klimatologiska och geologiska egenskaper. I jämförelse med tidigare studier, avseende andra delar av världen, belyses att förutsättningarna generellt sett är relativt fördelaktiga i Sverige. Likväl påvisar arbetet att betydande skillnader finns inom landet, vilket hänsyn bör tas till vid framtida planering.

Abstract [en]

The data center sector has expanded rapidly during the last decades, due to an increasing demand of digital services. Not the least in Sweden, where several big tech companies like Amazon Web Services and Microsoft are attracted by favorable characteristics. Server halls are energy intensive buildings, which globally causes considerable greenhouse gas emissions and water consumption. Accordingly, this creates an increasing need to monitor the environmental impact and optimize site selection. This thesis serves that demand by considering several aspects, to demonstrate an overall picture of the environmental impact from the sector in Sweden. In particular by quantifying the carbon- and water footprints and identifying sites with estimated lower environmental impact. The method includes collecting actual data (e.g. from questionary), along with using general data and methods from previous studies, to enable an estimate over the sectors electricity usage. Factors describing the greenhouse gas emission and water consumption per unit generated electricity, was determined for Sweden’s four electricity areas. This was done by relating the primary energy sources used for electricity production inside each area, with the purpose to derive the indirect footprint from electricity usage. The potential for strategically locating data centers was analyzed by classifying all municipalities, regarding parameters describing the possibility to reuse excess heat, availability of renewable energy, potential for free cooling and the risk of water scarcity. The result indicates that datacenters are responsible for 0,3 % of Sweden’s total greenhouse gas emissions (1,3 * 105 tonCO2eq/yr) and 14 % of all industries water usage (4,2 * 107 m3/yr). The footprint is largely due to the sector’s high electricity usage, responsible for around 5,4 % out of Sweden’s total electricity consumption during 2020. In general, the northern parts of Sweden were estimated to be more prominent in terms of lowering the carbon- and water footprint, due to beneficial climatological and geological factors. In comparison with previous studies, regarding other parts of the world, it also indicates that the characteristics in Sweden are overall relatively favorable. However this thesis also indicates significant differences within the country, which should be considered in future planning.

Place, publisher, year, edition, pages
2022. , p. 68
Keywords [sv]
Datacenter, Serverhall, Datahall, IKT, Miljöpåverkan, Elanvändning, Miljöavtryck, Koldioxidavtryck, Vattenkonsumtion, Strategisk lokalisering
National Category
Environmental Sciences Energy Engineering
Identifiers
URN: urn:nbn:se:lnu:diva-113592OAI: oai:DiVA.org:lnu-113592DiVA, id: diva2:1665235
Educational program
Environmental Risk Analysis Master Programme, 60 credits
Supervisors
Examiners
Available from: 2022-06-17 Created: 2022-06-07 Last updated: 2022-06-17Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Department of Biology and Environmental Science
Environmental SciencesEnergy Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 542 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf