Blickriktningens betydelse för resultatet vid mätning med phenolröd tråd
Linnaeus University, Faculty of Science and Engineering, School of Natural Sciences.
2012 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Introduktion: Torra ögon blir ett allt mer utbrett problem bland befolkningen då vi lever allt längre. Att på ett effektivt och för patienten smärtfritt sätt ställa diagnos är förstås önskvärt. Det går dock inte med ett ensamt test avgöra om en person lider av torra ögon utan det krävs en kombination utav tester. I en undersökning av Korb (2000), framgick det att de tillfrågade i första hand använde sig av anamnes, följt utav tear break-up time, fluorescein staining och på fjärde plats bland förstahandsvalen uppgavs rose bengal staining. Tester av tårstabilitet, staining och subjektiv upplevelse används enligt denna studie i mycket större utsträckning än kvantitetsmätningar. Det verkade finnas en viss frustration hos en del av de tillfrågade över bristen på standardisering vad gäller till exempel phenol röd tråd (PRT) och Schirmertest. Eventuella bevis för testernas tillförlitlighet och användbarhet skulle kanske innebära att de började användas i större utsträckning, förutsatt att det finns ett behov för det. I denna studie användes PRT och syftet var att ta reda på om resultatet varierar beroende på hur testet genomförs med avseende på blickriktningen. Det kom att ingå 30 st. individer med friska ögon i studien och det gjordes mätningar i blickriktning rakt framåt (BF), 20 grader inferiort (BI) samt 20 grader superiort (BS).

Resultat: 16 av de 30 deltagarna (53,3%) fick ett högre resultat BI jämfört med BF, 10 st. (33,3%) fick ett lägre resultat medan resterande fyra (13,3%) fick samma resultat BI och BF. Vid BS jmf. med BF fick 13 st. (43.3 %) ett högre resultat, 16 st. (53,3 %) ett lägre och en deltagare (3,33 %) fick samma resultat BS och BF. Students t-test visade inte på någon signifikant skillnad på resultaten mellan någon av blickriktningarna (p > 0,05). Vid normalisering utav var individs resultat och på nytt utfört t-test närmade sig resultatet en signifikant skillnad vid BF jmf. med BI (p = 0,067) och BI jmf. med BS (p = 0,073).

Slutsats: Det gick inte i denna studie att slå fast om blickriktningen har betydelse vid mätning med phenol röd tråd. En tendens mot att BI skulle kunna påverka resultaten på ett sådant sätt att de blir högre och BS så att de blir lägre jmf. med BF kunde dock ses.

Abstract [en]

Introduction: Dry-eye-disorders are becoming more common as the population is getting older. It is desirable with an effective and for the patient painless routine for diagnosing such disorders. One test alone is not enough to achieve this, but it requires a combination of different tests. In a study of Korb (2000), the most frequently test used was patient history followed by tear film break-up time (TBUT), fluorescein-staining and listed in fourth place among the primary tests was rose bengal-staining. According to this study testing the tear stability, the patient´s subjective experience and looking for staining is well used while measuring tear-quantity is not. Some of those who participated in Korb´s study seemed frustrated over the lack of standardization when it came to measuring tear flow and volume. Evidence of these test´s usefulness and reliability might result in more frequent using, presuming there is a need. In the study that follows PRT was used with the aim to determine whether the result differs with the direction of gaze during the test. Measurements were performed in straight forward gaze (FG), 20 degrees inferior (IG) as well as 20 degrees superior (SG) on 30 patients with healthy eyes.

Results: 16 of the 30 patients (53,3 %) got an higher result IG vs. FG, 10 (33,3 %) a lower while the four (13,3 %) remaining got the same result for these two directions. For the measurements SG vs. FG 13 (43.3 %) got a higher result, 16 (53,3 %) got a lower and one (3,33 %) got the same result for these two directions. Students t-test showed no significant difference between any of the directions (p > 0,05). Though after normalizing each individuals results and again performing t-test the values got closer to a significant difference FG vs. IG (p = 0,067) and IG vs. SG (p = 0,073).

Conclusion: It was not possible to conclude whether the direction of gaze influences the result when measuring with PRT. Though it showed a tendency towards that inferior gaze during the test might give higher values and superior gaze lower values, compared to straight forward gaze.

Place, publisher, year, edition, pages
2012. , p. 27
Keywords [sv]
phenolröd, tårvolym, blickriktning, tårfilm
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:lnu:diva-19637OAI: oai:DiVA.org:lnu-19637DiVA, id: diva2:532093
Subject / course
Optometry
Educational program
Optometry Programme, 180 credits
Uppsok
Medicine
Supervisors
Examiners
Available from: 2012-06-14 Created: 2012-06-08 Last updated: 2012-06-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
School of Natural Sciences
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 212 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf