lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The attitudes to CPAP treatment inventory: development and initial validation of a new tool for measuring attitudes to CPAP treatment.
Show others and affiliations
2011 (English)In: Journal of Sleep Research, ISSN 0962-1105, E-ISSN 1365-2869, Vol. 20, no 3, 460-471 p.Article in journal (Refereed) Published
Abstract [en]

Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS), but low adherence rates are common. The aim was to develop the attitudes to CPAP treatment inventory (ACTI), and to investigate the validity and reliability of the instrument among patients with OSAS. ACTI was developed on the basis of: (i) in-depth interviews with 23 patients; (ii) examination of the scientific literature; and (iii) consensus agreement of a multi-professional expert panel. This yielded five different types of attitudes to CPAP treatment. A prospective longitudinal design was used. Two-hundred and eighty-nine patients with OSAS were recruited at three different CPAP centres. Data were collected with ACTI and obtained from medical records. The homogeneity and internal consistency reliability were satisfactorily reflected by the item-total correlations (0.59-0.81) and Cronbach's alpha (0.89), respectively. Construct validity was confirmed with factor analysis (principal component analysis with orthogonal rotation; PCF). The PCF based on baseline data resulted in a one single-factor solution explaining 69% of the total variance. A confirmatory factor analysis was performed 2 weeks after CPAP initiation, resulting in the same factor solution. No indication of uniform differential item functioning was found. The predictive validity was tested with receiver operating characteristic analyses, and a cut-off of 10 on the ACTI gave a sensitivity of 93% and a specificity of 44% for CPAP termination within 6 months. The satisfactory measurement properties of this new pragmatic instrument are promising and indicate that ACTI can be useful in clinical practice to reliably measure attitudes to CPAP treatment.

Place, publisher, year, edition, pages
2011. Vol. 20, no 3, 460-471 p.
National Category
Medical and Health Sciences
Research subject
Health and Caring Sciences
Identifiers
URN: urn:nbn:se:lnu:diva-28957DOI: 10.1111/j.1365-2869.2010.00885.xPubMedID: 20819143Scopus ID: 2-s2.0-79960721555OAI: oai:DiVA.org:lnu-28957DiVA: diva2:649517
Available from: 2013-09-18 Created: 2013-09-18 Last updated: 2017-12-06Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedScopus

Authority records BETA

Årestedt, Kristofer

Search in DiVA

By author/editor
Årestedt, Kristofer
By organisation
School of Health and Caring Sciences
In the same journal
Journal of Sleep Research
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 133 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf