Metodjämförelse mellan två rörtyper avseende analys av TSH och fritt T4
Linnaeus University, Faculty of Health and Life Sciences, Department of Chemistry and Biomedical Sciences.
2013 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Idag är ett av förbättringsmomenten på sjukhusens laboratorier att minska turnaround-tiden. Genom minskad handläggningstid kommer provresultat att svaras ut fortare av laboratoriepersonal och samtidigt bidra till snabbare behandlingsåtgärd av läkarna. Vid akuta situationer används Rapid Serum tube-rör (RST) som har en koagulationstid på5 minuter, till skillnad från de vanliga Serum Separation Tube-rören (SST) som har en koagulationstid på 30 minuter. Önskemål finns från medicinläkare att kunna analysera tyreoideastimulerande hormon (TSH) samt fritt tyroxin (fT4) snabbare, vilket är möjligt om analyserna utförs på RST-rör.   Syftet med denna studie var att jämföra rörtyperna SST och RST med avseende på analys av TSH och fT4. TSH och fT4 analyserades med immunokemisk metod baserad på elektrokemiluminiscens (ECL). Analyserna genomfördes på instrumentet Cobas 6000. Studien syftade också till att kunna påverka sjukvårdsverksamheten genom att minska kostnader, turnaround-tiden och extra provtagningar för patienter.    De testpersoner som deltog i studien bestod av 30 män och 30 kvinnor. Deltagandet var frivilligt och proverna avkodades. Statistiska beräkningstester som använts är regressionsanalyser, student´s t-test, procentuella avvikelser samt acceptans eller förkastelse av nollhypoteser. Resultaten avseende TSH-analys uppgick till p=0,84 för alla deltagande, p=0,90 för kvinnor ochp=0,86för män. För fT4 uppgick resultaten till p=0,91 för alla deltagande, p=0,93 för kvinnor och p=0,94 för män med åsatt signifikansnivå 5 % (α = 0,05). Determinationskoefficenten (R2) uppgick till 1,0 för alla regressionsanalyser och Pearsons korrelationsvärde låg nära +1.    Studien visar att det är möjligt att analysera TSH och fT4 på RST-rören med instrumentet Cobas 6000.

Abstract [en]

To reduce turnaround time is one important step to give an adequate laboratory service. By reducing turnaround time test results will be delivered faster, and also contributing the medical doctors to make decision faster concerning patient´s diagnosis and medical treatment. In emergency situations Rapid Tube Serum tubes (RST) are used as clotting time is 5 minutes, in contrast to Serum Separator Tube-tubes (SST) with a clotting time of 30 minutes. Medical doctors have asked for a possibility to analyze thyroid stimulating hormone (TSH) and free thyroxine (fT4) faster, which is possible using RST-tubes.   The purpose of this study was to compare the two types of test tubes and see if there was a difference in concentration regarding TSH and fT4. TSH and fT4 were analysed with an immunochemical method based on electrochemiluminiscence (ECL), on the instrument Cobas 6000. The study also aimed to affect hospitals possibility to reduce costs by minimizing turnaround time and avoid extra blood tests for patients.    The participants in the study consisted of 30 men and 30 women. Participation was voluntary, and the samples were decoded. The statistical test calculations were regression analysis, student´s t-test, percentage deviations and acceptance or rejection of the null hypotheses.   The results for TSH-analyzes were p=0. 84for all participants, p=0. 90 for women andp=0. 86 for men. Test results for fT4 were p=0. 91 for all participants, p=0. 93 for women and p=0. 94 for men with affixed significance value of 5 % (α= 0.05). Determination coefficient (R2) was 1.0 for all regression analyzes and Pearson’s correlation coefficient was close to +1.   There is an adequate correlation between the analyte concentrations comparing SST- and RST-tubes. The results in this study show that it is possible to use RST-tubes for TSH and fT4-analysis.

Place, publisher, year, edition, pages
2013. , p. 19
Keywords [sv]
Sköldkörtel, S-TSH, S-ft4, RST, SST
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:lnu:diva-30089OAI: oai:DiVA.org:lnu-30089DiVA, id: diva2:661173
Subject / course
Biomedical Sciences
Educational program
Biomedical Laboratory Science Programme, 180 credits
Supervisors
Examiners
Available from: 2013-11-04 Created: 2013-11-01 Last updated: 2013-11-04Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Johansson, Malin
By organisation
Department of Chemistry and Biomedical Sciences
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 253 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf