A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis
Umeå universitet.
Umeå universitet.
Umeå universitet.
Umeå universitet.
Show others and affiliations
2013 (English)In: Hemodialysis International, ISSN 1492-7535, E-ISSN 1542-4758, Vol. 17, no 4, p. 612-617Article in journal (Refereed) Published
Abstract [en]

During hemodialysis (HD), microemboli develop in the blood circuit of the apparatus. These microemboli can pass through the venous chamber and enter into the patient's circulation. The aim of this study was to investigate whether it is possible to reduce the risk for exposure of microemboli by altering of the treatment mode. Twenty patients on chronic HD were randomized to a prospective cross-over study of three modes of HD: (a) a dry-stored dialyzer (F8HPS, Fresenius, steam sterilized) with a low blood level in the venous chamber (DL), (b) the same dialyzer as above, but with a high level in the venous chamber (DH), and (c) a wet-stored dialyzer (Rexeed, Asahi Kasei Medical, gamma sterilized) with a high blood level (WH). Microemboli measurements were obtained in a continuous fashion during 180 minutes of HD for all settings. A greater number of microemboli were detected during dialysis with the setting DL vs. WH (odds ratio [OR] 4.07, 95% confidence interval [CI] 4.03-4.11, P<0.0001) and DH vs. WH (OR 1.18, 95% CI 1.17-1.19, P<0.0001) and less for DH vs. DL (OR 0.290, 95% CI 0.288-0.2930.288-0.293, P<0.0001). These data indicate that emboli exposure was least when using WH, greater with DH, and most with DL. This study shows that using a high blood level in the venous chamber and wet-stored dialyzers may reduce the number of microemboli.

CallSend SMSAdd to SkypeYou'll need Skype CreditFree via Skype

Place, publisher, year, edition, pages
2013. Vol. 17, no 4, p. 612-617
Keywords [en]
Hemodialysis, microbubbles, microemboli, venous chamber, dialyzer, in vivo
National Category
Clinical Medicine
Research subject
Biomedical Sciences, Immunology
Identifiers
URN: urn:nbn:se:lnu:diva-33683DOI: 10.1111/hdi.12052ISI: 000325137100019OAI: oai:DiVA.org:lnu-33683DiVA, id: diva2:710933
Available from: 2014-04-08 Created: 2014-04-08 Last updated: 2017-12-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Nilsson Ekdahl, Kristina

Search in DiVA

By author/editor
Nilsson Ekdahl, Kristina
In the same journal
Hemodialysis International
Clinical Medicine

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 127 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf