Åpne denne publikasjonen i ny fane eller vindu >>Vise andre…
2013 (engelsk)Inngår i: Proceedings: 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED), IEEE, 2013, s. 485-490Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]
A high voltage and high power fault tolerant application of a resonant converter is presented. The resonant converter load shows frequent short circuits making the load voltage drop to zero within some us, implying high stress on the main circuit components. A load voltage short circuit fault tolerant system is suggested by including a novel way of augmenting the controller with a load voltage estimator. The estimator can detect load voltage short circuit and will then be a part of a fault tolerant high voltage resonant converter.
sted, utgiver, år, opplag, sider
IEEE, 2013
Emneord
Fault tolerant, load voltage short circuit estimator, resonant converter
HSV kategori
Identifikatorer
urn:nbn:se:lnu:diva-63167 (URN)10.1109/DEMPED.2013.6645759 (DOI)000396580800071 ()2-s2.0-84891074115 (Scopus ID)9781479900251 (ISBN)
Konferanse
2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013, 27 August 2013 through 30 August 2013, Valencia
2017-05-082017-05-082018-02-16bibliografisk kontrollert