lnu.sePublikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Horizontal Stabilisation of Sheathed Timber Frame Structures Using Plastic Design Methods - Introducing a Handbook Part 1: Design Principles for Horizontal Stabilisation
Luleå University of Technology.
Linnéuniversitetet, Fakulteten för teknik (FTK), Institutionen för byggteknik (BY).
2016 (Engelska)Ingår i: WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, Elsevier, 2016, s. 618-627Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The authors have developed a plastic design method for sheathed timber frame shear walls. It has been presented and discussed for inclusion in Eurocode 5 and a Swedish handbook has been presented. In the plastic method, you can choose to transfer the anchoring force via the leading stud to the substrate, corresponding to a fully anchored shear wall (no uplift of studs), but you can also choose to utilize the sheathings to transfer the tensile force via the sheathing-to-framing joints to the substrate by anchoring the bottom rail, corresponding to a partially anchored shear wall (studs experience uplift). By the plastic method several alternatives for anchoring the wall are possible and they can also be combined in such a way that each of them take a portion of the uplifting force, e.g. through a simple tying down device, through the sheathing-to-framing joints and through anchoring of the shear wall to the transverse wall. The method also makes it possible to include the load-bearing capacity of wall segments including openings. The handbook treats primarily shear walls, but for the sake of completeness some aspects of the roof and floor diaphragms are also discussed. The interior force distribution in sheathed timber frame walls weak in shear is discussed, as are the fundamental difference between the effect of vertical loads on the stabilisation of walls which are rigid or weak in shear, and how the plastic design method is applied to multi-storey timber buildings. (C) 2016 The Authors. Published by Elsevier Ltd.

Ort, förlag, år, upplaga, sidor
Elsevier, 2016. s. 618-627
Serie
Procedia Engineering, ISSN 1877-7058 ; 161
Nyckelord [en]
Horizontal stabilisatio, timber shear walls, plastic design methods, partially anchored, joints and anchorages, handbook
Nationell ämneskategori
Samhällsbyggnadsteknik
Forskningsämne
Teknik, Byggteknik
Identifikatorer
URN: urn:nbn:se:lnu:diva-59019DOI: 10.1016/j.proeng.2016.08.713ISI: 000387566500099Scopus ID: 2-s2.0-84997839798OAI: oai:DiVA.org:lnu-59019DiVA, id: diva2:1056776
Konferens
World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium (WMCAUS), JUN 13-17, 2016, Prague, CZECH REPUBLIC
Tillgänglig från: 2016-12-15 Skapad: 2016-12-14 Senast uppdaterad: 2016-12-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Källsner, Bo

Sök vidare i DiVA

Av författaren/redaktören
Källsner, Bo
Av organisationen
Institutionen för byggteknik (BY)
Samhällsbyggnadsteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 355 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf