lnu.sePublikationer
Driftmeddelande
För närvarande är det driftstörningar. Felsökning pågår.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Dimensional and ice content changes of hardened concrete at different freezing and thawing temperatures
Technical University of Denmark, Denmark.
2010 (Engelska)Ingår i: Cement & Concrete Composites, ISSN 0958-9465, E-ISSN 1873-393X, Vol. 32, nr 1, s. 73-83Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

Samples of concrete at different water-to-cement ratios and air contents subjected to freeze/thaw cycles with the lowest temperature at about -80 degrees C are investigated. By adopting a novel technique, a scanning calorimeter is used to obtain data from which the ice contents at different freeze temperatures can be calculated. The length change caused by temperature and ice content changes during test is measured by a separate experiment using the same types of freeze-thaw cycles as in the calorimetric tests. In this way it was possible to compare the amount of formed ice at different temperatures and the corresponding measured length changes. The development of cracks in the material structure was indicated by an ultra-sonic technique by measuring on the samples before and after the freeze-thaw tests. Further the air void structure was investigated using a microscopic technique in which air'bubble' size distributions and the so-called spacing factor, indicating the mean distance between air bubbles, were measured. By analyzing the experimental result, it is concluded that damages occur in the temperature range of about -10 degrees C to -55 degrees C, when the air content is lower than about 4% of the total volume. For a totally water-saturated concrete, damages always occur independently of the use of entrained air or low water-to-cement ratios. It is, further, concluded that the length changes of these samples correspond to the Calculated ice contents at different temperatures in a linear fashion. @ 2009 Elsevier Ltd. All rights reserved.

Ort, förlag, år, upplaga, sidor
2010. Vol. 32, nr 1, s. 73-83
Nyckelord [en]
Durability, Freezing, Frost damages, Scanning calorimeter, Ice content, Thawing
Nationell ämneskategori
Byggproduktion
Identifikatorer
URN: urn:nbn:se:lnu:diva-48719DOI: 10.1016/j.cemconcomp.2009.09.001OAI: oai:DiVA.org:lnu-48719DiVA, id: diva2:893459
Tillgänglig från: 2016-01-12 Skapad: 2016-01-12 Senast uppdaterad: 2017-11-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Johannesson, Björn

Sök vidare i DiVA

Av författaren/redaktören
Johannesson, Björn
I samma tidskrift
Cement & Concrete Composites
Byggproduktion

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 178 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf