lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Identification of the running status of membrane walls in an opposed fired model boiler under varying heating loads
Shandong University, China.
Xi'an Jiaotong University, China.
Xi'an Jiaotong University, China.
Linnaeus University, Faculty of Technology, Department of Built Environment and Energy Technology. Linnaeus University, Linnaeus Knowledge Environments, Advanced Materials. (Bioenergy)ORCID iD: 0000-0001-8964-116X
Show others and affiliations
2020 (English)In: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 173, p. 1-9, article id 115217Article in journal (Refereed) Published
Sustainable development
SDG 7: Ensure access to affordable, reliable, sustainable and modern energy for all, SDG 13: Take urgent action to combat climate change and its impacts by regulating emissions and promoting developments in renewable energy
Abstract [en]

To understand the running status of membrane walls in an opposite firing boiler, a scale-down model furnace was established, and the temperature, heat flux, strain and stress distributions are investigated under four heating loads. Results show that the average membrane wall temperature and heat flux present a continuous increase from 42 oC and 16 W/m2 to 96 oC and 50 W/m2, respectively, with the heating load increase from 25% to full load. The average strain and stress also rise from 88.7 µm and 0.094 MPa to 152.5 µm and 0.148 MPa when the heating load increases from 25% to 50%, but then they keep stable when further increasing the heating load. General distribution patterns of each tested parameter are found relatively similar under varying heating loads. High strain and stress distributions are always detected at the middle left zone of side walls and the middle of the rear wall, where wall temperatures are measured high. External fixed constraints and high-temperature thermal strain is found jointly affecting the strain and stress distribution of the membrane wall. A simplified mechanism of how the strain and stress on boiler membrane walls evolve is proposed after comprehensive discussion of the measurement results.

Place, publisher, year, edition, pages
Elsevier, 2020. Vol. 173, p. 1-9, article id 115217
Keywords [en]
Opposed fired boiler, Membrane walls, Heat flux, Strain and stress, Fixed constraint
National Category
Bioenergy
Research subject
Technology (byts ev till Engineering), Bioenergy Technology
Identifiers
URN: urn:nbn:se:lnu:diva-93089DOI: 10.1016/j.applthermaleng.2020.115217ISI: 000526111200039Scopus ID: 2-s2.0-85082182891OAI: oai:DiVA.org:lnu-93089DiVA, id: diva2:1416465
Available from: 2020-03-23 Created: 2020-03-23 Last updated: 2026-04-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Lin, Leteng

Search in DiVA

By author/editor
Lin, Leteng
By organisation
Department of Built Environment and Energy TechnologyAdvanced Materials
In the same journal
Applied Thermal Engineering
Bioenergy

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 237 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf