An experimental study of thermal performance of the radiant ceiling cooling in office building in Thailand
King Mongkut’s University of Technology Thonburi, Thailand. (Sustainable Built Environment Research)ORCID iD: 0000-0002-8397-6046
King Mongkut’s University of Technology Thonburi, Thailand.
King Mongkut’s University of Technology Thonburi, Thailand.
2023 (English)In: Energy and Buildings, ISSN 0378-7788, E-ISSN 1872-6178, Vol. 283, article id 112849Article in journal (Refereed) Published
Abstract [en]

This paper investigated the radiant ceiling cooling in office buildings in a tropical hot humid climate. Full-scale experiments were conducted in an outdoor laboratory chamber to observe the indoor thermal conditions and the envelope heat gain from the intermittent operation of the installed radiant chilled panels (RCP) coupled with an outdoor air unit (OAU). The radiant system was also modeled by using a simulation software namely Transient System Simulation Software (TRNSYS), and the calculation results from the model were compared to the experimental observations. In the simulation part, the validated TRNSYS model was adopted to assess the radiant system performance in a typical office environment under the four schemes of combinations of the technology options for the OAU and the building envelope. The perceived comfort from the radiant cooling was assessed based on the thermal sensation of the local subjects acclimatized to hot humid climate. The energy consumption of the radiant cooling was also apprised as opposed to the conventional mixed-air system. The simulation results presented an insight into the importance of the exhaust air heat recovery and the envelope insulation on energy saving and human comfort improvement for the radiant cooling.

Place, publisher, year, edition, pages
Elsevier BV , 2023. Vol. 283, article id 112849
Keywords [en]
Radiant ceiling cooling, Subjective thermal comfort, Thermal performance, Tropical hot humid climate, Ceilings, Computer software, Energy conservation, Energy utilization, Office buildings, Tropics, Waste heat, Air units, Hot humid climate, Outdoor air, Radiant cooling, Radiant systems, Simulation software, Thermal comfort
National Category
Energy Engineering
Research subject
Technology (byts ev till Engineering)
Identifiers
URN: urn:nbn:se:lnu:diva-138456DOI: 10.1016/j.enbuild.2023.112849Scopus ID: 2-s2.0-85147246744OAI: oai:DiVA.org:lnu-138456DiVA, id: diva2:1957570
Available from: 2025-05-11 Created: 2025-05-11 Last updated: 2025-05-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Aryal, Ashmin

Search in DiVA

By author/editor
Aryal, Ashmin
In the same journal
Energy and Buildings
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 141 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf