Dry-etch fabrication of free-standing SiNx nanocalorimeter membranes
2026 (English)Independent thesis Advanced level (degree of Master (Two Years)), 30 credits / 45 HE credits
Student thesis
Abstract [en]
In experimental physics, measuring specific heat is essential to characterize materials and study phase transitions. The ability to quantify heat capacity using a variety of methods, including adiabatic, thermal relaxation, and AC calorimetry, facilitates the investigation of numerous aspects of a broad range of materials. (Kondedan, 2023) Measuring of specific heat with mass of 1 mg can be obtained with standard commercial calorimeters, but when mass of sample is lower than that, the specific heat of device will be greater than sample and we won’t have accurate result, in condensed matter Physics low range mass (Micrograms range) provides temperature uniformity, phase purity, high quality sample and accurate measurements in extreme conditions like high magnetic field (Tagliati and Rydh, 2012). To achieve this purpose, a few groups were fabricating micro- and nanocalorimeters, which work to obtain specific heat for a particular aim of study; they are constructed for different sample sizes and different temperatures (Greene et al., 1972; Early et al., 1981;Stewart, 1983). Also development of the calorimeter for small samples was presented in the work of (Denlinger et al., 1994), which was helpful. At Stockholm University, the development of a differential membrane nanocalorimeter for measuring specific heat in high magnetic fields and low temperatures is active. (Tagliati, 2011; Tagliati et al.,2012) They developed a membrane-based AC calorimeter over the years. (Kondedan,2023; Tagliati, 2011; Tagliati et al., 2012; Campanini, 2019; Tagliati et al., 2010; Tagliati and Rydh, 2011; Tagliati and Rydh, 2012) This thesis presents the methods of dry etching that work for making free-standing SiN membranes for differential membrane nanocalorimeters. Free-standing membrane is achieved by the plasma etching method; this method was tested for the wafers with 525 μm thickness and 500 nm SiN thickness on both sides and finally was tested for real nano-calorimeters after device fabrication. Our results show that these techniques work for the differential nano-calorimeters instead of the wet etching technique, which is a time-consuming technique. The key point of etching is when there is a very close distance to reach the SiN membrane. Since the SiN membrane is so fragile, accuracy in measurement of etching depth and time is very important. In this project, we tried to understand which factors should be considered when we are so close to the membrane and when the etching should be stopped to have a clear and not broken membrane. Also, we understood that the control of the etching rate depends on the uniformity of the silicon substrate and how the wafer is exposed by the plasma in the chamber. Different tests were done to understand how to control etching, and the results were used to fabricate the completed differential membrane-based nanocalorimeters. The preliminary fabrications were overetched, but in other tries, 2/3 of the final devices were split out from the wafer and sent for screening in the USA, and 1/3 of them remained at Stockholm University.
Place, publisher, year, edition, pages
2026. , p. 32
Keywords [en]
Nanocalorimeter, Dry etch, SiN
National Category
Nanotechnology for Electronic Applications
Identifiers
URN: urn:nbn:se:lnu:diva-149920OAI: oai:DiVA.org:lnu-149920DiVA, id: diva2:2107568
External cooperation
Stockholm University
Educational program
Physics, masterprogramme, 120 credits
Supervisors
Examiners
2026-10-062026-10-042026-10-06Bibliographically approved