Concentrated load capacity of HC500 hollow core floor –Experimental study
Cracow University of Technology, Poland; Consolis Group Technology Development Centre, Poland.
Linnaeus University, Faculty of Technology, Department of Building Technology. Cracow University of Technology, Poland.ORCID iD: 0000-0001-6133-3624
2026 (English)In: Fib Symposium, fib. The International Federation for Structural Concrete , 2026Conference paper, Published paper (Refereed)
Abstract [en]

Precast prestressed hollow core floors are often subjected to concentrated loads applied to one of the precast units forming the floor. Due to the presence of cast on site joints, interconnecting adjacent elements, the capacity of the whole floor system is expected to exceed that of a single plate. In order to study the concentrated load capacity, an experiment on a full-scale hollow core floor was performed. The floor consisted of 6 identical hollow core elements of 500 mm depth and 15 m span. Eccentric concentrated loads were applied in two positions – on the free edge of the floor and on its center, one load position at a time. The loads were applied over three webs and increased till failure. The floor experiment was accompanied by a single plate experiment where one slab, with similar boundary conditions and same geometry, was subjected to an analogous loading increased till failure. The floor capacity in the edge and central position was 1.51 and 2.38 times higher than the single element, respectively. While the single element behaved ductile, resulting in shear flexural failure, the failure modes of floor experiments were different, dominated by transverse flexure and brittle. Obtained results show that hollow core slabs subjected to concentrated loads, considered as a part of a floor system, are characterized by a significant capacity margin when compared to single, isolated elements. Failure modes of floors can largely differ from those observed in single elements.

Place, publisher, year, edition, pages
fib. The International Federation for Structural Concrete , 2026.
Keywords [en]
hollow core, load distribution, precast concrete, prestressed concrete
Identifiers
URN: urn:nbn:se:lnu:diva-150893Scopus ID: 2-s2.0-105051213544ISBN: 9782940643318 (print)OAI: oai:DiVA.org:lnu-150893DiVA, id: diva2:2115270
Available from: 2026-11-04 Created: 2026-11-04 Last updated: 2026-11-04

Open Access in DiVA

No full text in DiVA

Scopus

Authority records

Derkowski, Wit

Search in DiVA

By author/editor
Derkowski, Wit
By organisation
Department of Building Technology

Search outside of DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf