lnu.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Experimental Analysis of a Novel Hybrid Timber-Concrete-Steel Flooring System
Linnaeus University, Faculty of Technology, Department of Building Technology.ORCID iD: 0000-0001-5304-2368
Università degli Studi di Reggio Calabria, Italy.
Linnaeus University, Faculty of Technology, Department of Building Technology. Cracow University of Technology, Poland.ORCID iD: 0000-0001-6133-3624
2026 (English)In: Lecture Notes in Civil Engineering, Springer Nature, 2026, Vol. 942 LNCEConference paper, Published paper (Refereed)
Abstract [en]

This study investigates a sustainable, novel composite floor system integrating steel, concrete, and timber members in a prefabricated unit, with the aim of evaluating both structural and environmental performance. Preliminary investigations included numerical analyses, the fabrication of two mock-ups, and an experimental campaign to assess the dynamic and static behavior of a floor unit. The mock-ups differed in the timber chord configuration and the arrangement of the steel diagonals, while the geometry of the upper concrete slab remained unchanged. This paper presents only the results of the experimental static tests conducted until failure, conducted at the Laboratory of the Department of Building Technology at Linnaeus University in Växjö (Sweden). Two specimens were tested under a four-point bending test to investigate the flexural behavior and failure modes. Initially, the specimens were subjected to serviceability limit state (SLS) loading, applied in three cycles. Subsequently, three loading cycles were applied under the design ultimate limit state (ULS). Finally, each specimen was loaded under monotonic static loading until failure. Both Specimen S1 and Specimen S2 showed consistent behavior during all three SLS loading cycles. At collapse, detachment of the diagonals from the bottom chord was observed, while the steel diagonal connections to the upper concrete slab performed as intended throughout the test duration. The discussion focuses primarily on the behavior of the connections between the timber bottom chords and the thin-walled steel diagonal members, as these elements governed the global response and failure mechanisms. Based on the observed failure modes, the paper also discusses possible improvements to enhance the overall system performance.

Place, publisher, year, edition, pages
Springer Nature, 2026. Vol. 942 LNCE
Keywords [en]
Composite Floor System, Experimental Investigation, Serviceability Limit State (SLS), Timber-steel Connections, Ultimate Limit State (ULS)
Identifiers
URN: urn:nbn:se:lnu:diva-150888DOI: 10.1007/978-3-032-39505-4_51Scopus ID: 2-s2.0-105054600187ISBN: 9783032395047 (print)OAI: oai:DiVA.org:lnu-150888DiVA, id: diva2:2115292
Available from: 2026-11-04 Created: 2026-11-04 Last updated: 2026-11-04

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Amaddeo, CarmenDerkowski, Wit

Search in DiVA

By author/editor
Amaddeo, CarmenDerkowski, Wit
By organisation
Department of Building Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 8 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf